CLI
Programming and controlling unit for ILIA linear detectors

CONTROLLER for programming, managing, monitoring, calibrating, and performing remote tests for Linear Detectors of the ILIA line.
ERHS0712, ILIA Tx / Rx version.
ERRHS0712, ILIA Reflection version TRx.
ERHS0712-1013, ILIA Tx / Rx version RAL 1013 PEARL WHITE.
ERRHS0712-1013, ILIA Reflection version TRx RAL 1013 PEARL WHITE.
ERHS0712-PRO, ILIA Tx / Rx PRO version.
ERHS0712-PRO-L, ILIA Tx / Rx PRO version WITH DUST PROOF EXTENSION PIPE.
Standard
EN54-12, Linear beam detector; EN54-18, input/output modules for fire detection plants. The certification makes it possible to install the system for protection up to 12,000 sqm in full configuration with 8 ILIA detectors and redundant power supply.






Features
- Connection from 1 to 8 ILIA detectors, even of different model. Expansion board up to 8 detectors (optional).
- Alarm and fault outputs for each individual detector connected.
- Pre-alarm outputs, in the PRO version only, distinct for each single detector.
- General alarm outputs, fault (delayed), maintenance request and pre-alarm (this last feature only in the version PRO).
- Double RS485 serial line for open lines or loop, even with one connected detector only.
- Double independent power input.
- Operational access to the programming keyboard protected by password.
- Selectable language menu (ITALIAN / ENGLISH / GERMAN/ POLISH).
- Clock and Calendar.
- 128×64 pixel graphic display with full event description.
- Store events for each single detector, with real-time status analysis and recording range adjustable by menu.
- Store event and time logs. Possibility to read logs from PC via USB.
- Alarms reset by specific menu and / or control panel via dedicated reset input.
- Cabling facilitation.
- N° 20 cable inputs from the bottom side.
- Predisposition for internal mounting plate and DIN rail.
- Field installation at ground level.
- Protection rate IP65.
- RoHS Compliance.
- Full compatibility with ILIA line detectors as in Tx-Rx version that in Reflection version, produced since May 2009 and with short isolator base.
- Available in versions: CLI or CLI – PRO.
Available versions
CLI
Version change selectable by menu:
- CLI, for standard civil and industrial environments, in the absence of dust, steam or vapors in suspension.
- DUST, for environments with intense vapors, dust and suspended aerosols.
- FROST, for environments with water vapor or mists in the working phases, open sheds cold storages.
CLI-PRO
For installations in environments where high sensitivity with double alarm thresholds is needed. NOTE version to be combined exclusively with the ERHS0712-PRO or ERHS0712-PRO-L models.
CONTROLLER | CLI | CLI-PRO | ||
MODEL | CLI | DUST | FROST | CLI-PRO |
NUMBER OF CONNECTABLE DETECTORS | from 1 to 8 | from 1 to 8 | from 1 to 8 | from 1 to 8 |
STANDARD DOUBLE SERIAL PORT | ![]() | ![]() | ![]() | ![]() |
PREALARM OUTPUTS | ![]() | ![]() | ![]() | ![]() |
FAULT OUTPUTS (DELAYED) | until 90s | until 90s | until 90s | until 254s |
PREALARM OUTPUTS | ![]() | |||
MAINTENANCE REQUEST OUTPUT | ![]() | ![]() | ![]() | |
EVENT LOG | ![]() | ![]() | ![]() | ![]() |
- standard
Compatibility of ILIA models
CONTROLLER | CLI | CLI-PRO | |||
---|---|---|---|---|---|
MODEL | CLI | DUST | FROST | CLI-PRO | |
TX-RX VERSION | ERHS0712 – ERHS0712-1013 | ERHS0712 – ERHS0712-1013 | ERHS0712 – ERHS0712-1013 | ERHS0712-PRO | ERHS0712-PRO-L |
TRX VERSION | ERRHS0712 – ERRHS0712-1013 | ERRHS0712 – ERRHS0712-1013 | ERRHS0712 – ERRHS0712-1013 | – | – |
DUST REJECTION | ![]() | ![]() | ![]() | ![]() | |
FOG REJECTION | ![]() | ![]() | ![]() | ||
DUST PROOF EXTENSION PIPE | ![]() |
- standard





